This UPS is designed to deliver reliable and consistent power to your equipment, even in the most demanding environments. The 2U form factor makes it easy to install and integrate with your existing IT infrastructure.
The 9PXRT2U features an online double conversion topology, which ensures that power is always clean and consistent, even when the input power is unstable. It also includes an automatic bypass feature, which allows for continuous power to your equipment even in the event of a UPS malfunction or overload.
The UPS comes with an intuitive LCD display that provides real-time information on the status of the UPS, including battery runtime, load capacity, and input/output voltage. Additionally, the 9PX3000IRT2U is equipped with advanced management capabilities, including remote management and monitoring, which makes it easy to manage the UPS from anywhere in the world.
Overall, the Eaton 9PX 2U Online RT UPS is a reliable and efficient power protection solution that delivers high-quality power to your critical IT infrastructure, ensuring that your equipment remains up and running, even in the event of a power outage or other power-related issues.
Features
- Double conversion topology
- Sine Wave
- Constantly monitors power conditions and regulates voltage and frequency
- First UPS in its class to provide Unity power factor (VA=W)
- Energy Star qualified, provides the highest efficiency level to reduce energy and cooling costs
- Internal bypass allows service continuity in case of UPS fault
- Next-generation graphical LCD display
- Compatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)
- Meter energy consumption (down to the managed outlet groups)
- Hot swappable batteries
- Advanced Battery Management (ABM) technology to increase battery lifetime
- Long backup time with up to 4 optional EBM
- Battery rating: 12 V / 9 Ah
- Battery type: Sealed, lead-acid
- Extended battery capability: Yes
Eaton 9PX UPS, 3000 VA, 3000 W, Input: C20, Outputs: (8) C13, (2) C19, Rack/tower, 2U
- Battery quantity: 6
- Receptacle: (8) C13, (2) C19
- Topology: Online/Double-conversion
- Wattage: 3000 W
- VA rating: 3000 VA
- Output waveform: Sine wave
- Voltage: 230V
- Output power factor: 1
- Output nominal voltage: 230V default (200/208/220/230/240V)
- Output voltage range: 200/208/220/230/240 V +/- 1%
- Voltage distortion output (linear load) – max: 3
- Output frequency: 50/60 Hz
- Feed type: 1
- Input connection: C20 <a
- Input cord length: 1.8m
- Input nominal voltage: 230V default (200/208/220/230/240V)
- Input voltage range: 176-276 V (100-276 V with derating)
- Nominal frequency: 50/60 Hz
- Input frequency range: 40-70 Hz
- Input power factor: >.99
Eaton 9PX UPS, 2200 VA, 2200 W, Input: C20, Outputs: (8) C13, (2) C19, Rack/tower, 2U
- Battery quantity: 6
- Receptacle: (8) C13, (2) C19
- Topology: Online/Double-conversion
- Wattage: 2200 W
- VA rating: 2200 VA
- Output waveform: Sine wave
- Voltage: 230V
- Output power factor: 1
- Output nominal voltage: 230V default (200/208/220/230/240V)
- Output voltage range: 200/208/220/230/240 V +/- 1%
- Voltage distortion output (linear load) – max: 3
- Output frequency: 50/60 Hz
- Feed type: 1
- Input connection: C20 <a
- Input cord length: 1.8m
- Input nominal voltage: 230V default (200/208/220/230/240V)
- Input voltage range: 176-276 V (100-276 V with derating)
- Nominal frequency: 50/60 Hz
- Input frequency range: 40-70 Hz
- Input power factor: >.99
- Voltage distortion output (linear load) – max: 3
Eaton 9PX UPS, 1500 VA, 1500 W, Input: C14, Outputs: (8) C13, Rack/tower, 2U
- Battery quantity: 4
- Receptacle: (8) C13
- Topology: Online/Double-conversion
- Wattage: 1500 W
- VA rating: 1500 VA
- Output waveform: Sine wave
- Voltage: 230V
- Output power factor: 1
- Output nominal voltage: 230V default (200/208/220/230/240V)
- Output voltage range: 200/208/220/230/240 V +/- 1%
- Voltage distortion output (linear load) – max: 3
- Output frequency: 50/60 Hz
- Feed type: 1
- Input connection: C20 <a
- Input cord length: 1.8m
- Input nominal voltage: 230V default (200/208/220/230/240V)
- Input voltage range: 176-276 V (100-276 V with derating)
- Nominal frequency: 50/60 Hz
- Input frequency range: 40-70 Hz
- Input power factor: >.99
- Voltage distortion output (linear load) – max: 3
Eaton 9PX UPS, 1000 VA, 1000 W, Input: C14, Outputs: (8) C13, Rack/tower, 2U
- Battery quantity: 4
- Receptacle: (8) C13
- Topology: Online/Double-conversion
- Wattage: 1000 W
- VA rating: 1000 VA
- Output waveform: Sine wave
- Voltage: 230V
- Output power factor: 1
- Output nominal voltage: 230V default (200/208/220/230/240V)
- Output voltage range: 200/208/220/230/240 V +/- 1%
- Voltage distortion output (linear load) – max: 3
- Output frequency: 50/60 Hz
- Feed type: 1
- Input connection: C20 <a
- Input cord length: 1.8m
- Input nominal voltage: 230V default (200/208/220/230/240V)
- Input voltage range: 176-276 V (100-276 V with derating)
- Nominal frequency: 50/60 Hz
- Input frequency range: 40-70 Hz
- Input power factor: >.99
- Voltage distortion output (linear load) – max: 3